| Price |
inc. VAT
|
| Force Range (Fn) | 100; 200; 500 N; 1; 2; 5; 10; 20; 50 kN |
|---|---|
| Overload | |
| - Safe | 130 % Fn |
| - Ultimate | 150 % Fn |
| - Permanent Static Load | 75 % Fn |
| - Dynamic Load | 50 % Fn |
| Sensors with Voltage Output | |
| - Min. Load Impedance (RL) | 2 kΩ |
| Sensors with Current Output | |
| - Max. Load Impedance (RL) | 500 kΩ |
| Excitation | |
| - Supply Voltage | 24 ± 10 % VDC |
| - Current Consumption (max) | 40 mA |
| Max. Error | |
| - Non-linearity | 0,25 % F.S. |
| - Hysteresis | 0,25 % F.S. |
| - Creep (30 min) | 0,1 % F.S. |
| Temperature Effect | |
| - Zero | 0,15 % F.S./10 °C |
| - Output | 0,15 % F.S./10 °C |