| Price |
inc. VAT
|
| Force range (Fn) | 1; 2; 5 kN | 10; 20; 50 kN |
|---|---|---|
| Overload | ||
| - Safe | 130 % Fn | |
| - Ultimate | 150 % Fn | |
| - Permanent Static Load | 75 % Fn | |
| - Dynamic Load | 50 % Fn | |
| Sensors with Voltage Output | ||
| - Min. Load Impedance (RL) | 2 kΩ | |
| Sensors with Current Output | ||
| - Max. Load Impedance (RL) | 500 kΩ | |
| Excitation | ||
| - Supply Voltage | 24 ± 10 % VDC | |
| - Current Consumption (max) | 40 mA | |
| Max. Error | ||
| - Non-linearity | 0.25 % F.S. | 0.5 % F.S. |
| - Hysteresis | 0.25 % F.S. | 0.5 % F.S. |
| - Creep (30 min) | 0.1 % F.S. | 0.5 % F.S. |
| Temperature Effect | ||
| - Zero | 0.15 % F.S./10°C | |
| - Output | 0.15 % F.S./10°C | |