| Price |
inc. VAT
|
| Force Range (Fn) | 500 N; 1; 2; 5; 10; 20; 50; 100; 200 kN |
|---|---|
| Overload | |
| - Safe | 130 % F.S. |
| - Ultimate | 200 % F.S. |
| - Permanent Static Load | 75 % F.S. |
| - Dynamic Load | 50 % F.S. |
| Sensor with Voltage Output | |
| - Min. Load Impedance (RL) | 10 kΩ |
| Sensor with Current Output | |
| - Max. Load Impedance (RL) | 500 Ω |
| Power Supply | |
| - Supply Voltage | 24 VDC ± 10 % |
| - Max. Current Consumption | 40 mA |
| Max. Error | |
| - Non-linearity | 0.2 % F.S. |
| - Hysteresis | 0.2 % F.S. |
| Temperature Effect | |
| - Zero | 0.15 % F.S./10°C |
| - Output | 0.15 % F.S./10°C |
| Temperature Range | |
| - Nominal | 0 ... 50 °C |
| - Operating | -10 ... 60 °C |
| Protection | IP54 |
| Cable | |
| - Type | LiYCY 4 x 0.14 |
| - Length | 2 m |